background image

 

 

S5864 Hardware Installation Manual

 

 

Summary of Contents for S5864

Page 1: ...S5864 Hardware Installation Manual...

Page 2: ...2 4 Electrostatic Discharge Damage Prevention 7 2 3 Requirements for Common Locations 7 2 3 1 Environment 7 2 3 2 Location Configuration Prevention 7 2 3 3 Cabinet Configuration 7 2 3 4 Power Require...

Page 3: ...1 USB Interface 15 3 4 Checking After Installation 15 Chapter 4 Maintaining Switch 17 4 1 Opening the Machine Box 17 4 2 Closing Machine Box 18 Chapter 5 Hardware Fault Analysis 19 5 1 Fault Separatio...

Page 4: ...5 2 Indicator Description 19 II...

Page 5: ...e LINK ACT indicator 40GE optical port QSFP interface LINK ACT indicator Console port RJ45 interface a rate of 9600bps Ethernet management port RJ45 interface USB interface USB interface S5864 has 5 h...

Page 6: ...swap fan modules 1 2 S5864 Systematic Characteristic Parameters Protocol standard Supported standard IEEE 802 1d Spanning Tree Protocol IEEE 802 1s multiple spanning trees IEEE 802 1p Class of Service...

Page 7: ...gigabit management interface Dimensions mm W D H 442 5 404 44 Operating temperature humidity 0 40 10 85 non condensing Storagetemperature humidity 40 80 5 95 non condensing Power characteristics Input...

Page 8: ...ther electronic products the semiconductor chip easily gets damaged if you power on or off abruptly and frequently To restart up the switch of S5864 you have to open the power on off after the power i...

Page 9: ...the sleeve avoiding stumbling the machine box Put on the protective glasses if the environment may cause damage to your eyes Avoid incorrect operations that may cause damage to human or devices 2 2 2...

Page 10: ...eckout 6 If trouble happens take the following measures A Cut off the system s power B Alarm C Take proper measures to help persons who are hit by the disaster Artificial respiration is needed if nece...

Page 11: ...is sealed because the opened machine box will reverse the cool air flow 2 3 3 Cabinet Configuration The following content assists you to make a proper cabinet configuration Each device on the cabinet...

Page 12: ...Tools and Device The tools and devices to install the S5864 switch are not provided by the S5864 switch You yourself need to prepare them The following are the tools and devices needed for the typica...

Page 13: ...hing 4 5 kg or over 4 5 kg on the top of the switch 3 2 2 Installing the Machine Box on the Cabinet The machine box of the switch is fixed on the cabinet through the brackets When you fix the brackets...

Page 14: ...emulation software such as super Windows terminal The cable is provided according to the host The communication parameters of the terminal serial port can be set to a rate of 9600bps eight data bits...

Page 15: ...cable is DB9 The RJ45 plug is put into the socket of the console port on the S5864 switch The inner line connection in the cable is shown in figure 3 1 The console cable is numbered as RLC0301 Figure...

Page 16: ...tors are used to indicate the LINK ACT state The ports can connect other Ethernet terminal devices through the UTP port and the direct through or cross network cable The numbering order of the pins in...

Page 17: ...normal phase of data 2 TP2 5 Sending receiving the paraphase of the data 2 TP2 6 Sending receiving the paraphase of the data 1 TP1 7 Sending receiving the normal phase of data 3 TP3 8 Sending receivin...

Page 18: ...ng the 40GE QSF port and other Ethernet terminals 2 Set the ports to 4 10GE ports You can connect the QSFP optical module to the optical port and then you can connect other Ethernet terminal devices w...

Page 19: ...ution The switch shown in figure 3 10 does not represent the material S5864 1 3 1 USB Interface S5864 provides with 1 USB2 0 interface Figure 3 11 Connecting USB2 0 interface 3 4 Checking After Instal...

Page 20: ...strong If the switch is installed on the desk check whether there is enough space for the switch to discharge its heat and whether the desk is stable Check whetherthe connected power meets the power r...

Page 21: ...ution When the power cable still connects the power source do not touch it When you open the cover the switch you may use the following tools Crossed screwdriver Static armguard Perform the following...

Page 22: ...e switch on the cabinet or the desk 5 Reconnect all cables of the switch Chapter 5 Hardware Fault Analysis The part describes how to remove the fault from the switch 5 1 Fault Separation The key for r...

Page 23: ...baud rate of 9600 bps eight data bits no sum check bit one stop bit and no traffic control 5 2 Indicator Description The LED indicator shows that the switch is running The following table shows the in...

Page 24: ...10GE ports The 4 port indicators are on in turn The interval between two indicators is 5 seconds The indicators combing with BREAKOUT indicators show the state of 10GE ports 40GE BREAKOUT 1 4 The 40G...

Page 25: ...ce names and company names which are written in this manual but do not belong to the company belong to their owners respectively Disclaimer of warranty provides no evident or hinted guarantee towards...

Reviews: