S2510-B Hardware Installation Manual

Summary of Contents for S2510-B

Page 1: ...S2510 B Hardware Installation Manual...

Page 2: ...4 Installation Tools and Device 7 Chapter 3 Installing the S2510 B Switch 8 3 1 Installation Procedure of S2510 B 8 3 2 Installing the Chassis of S2510 B 8 3 2 1 Installing the Chassis on the Desk 8 3...

Page 3: ...n UTP RJ45 port Gigabit SFP port SFP port 100 1000M SFP port Link ACT indicators Console port A rate of 9600bps RJ45 interface Figure 1 1 Front template of the S2510 B switch Table 1 2 Parts at the fr...

Page 4: ...S2510 B switch Table 1 2 Parts at the back template of the S2510 B switch No Abbrev Name Remarks 1 Fan 2 AC power socket 100 240V AC 3 Grounding column The grounding must be fine 1 2 Characteristic Pa...

Page 5: ...ation 8 gigabit Ethernet ports 1 console port 2 SFP ports Dimensions W D H mm 280 180 44 Working temperature humidity 0 40 10 90 non condensing Storage temperature humidity 40 70 5 90 non condensing P...

Page 6: ...zontal with the power socket 2 When the lifetime of our products ends handle them according to national laws and regulations or send these products to our company for collective processing Caution Whe...

Page 7: ...les connect the power to the ground short circuit happens and components may be damaged Please cut off the direct current connection when you operate the hull or work near the power supply When the po...

Page 8: ...s is well discharged and sufficient air circulation is provided for device cooling Put the chassis at the place where cool air can blow off the heat inside the chassis Make sure the chassis is sealed...

Page 9: ...e good grounding or the input power disturbs too much and excessive pulses exist the error code rate of communication devices increases and even the hardware system will be damaged 2 4 Installation To...

Page 10: ...S2510 B The chassis of the switch can be put on the desk or fixed to the DIN slide Your network installation requirements can be met if you conduct the operations according to the following procedure...

Page 11: ...3 1 Connecting the Console Port The switch of S2510 B has a console port and its rate is a value ranging from 1200 to 115200 bps It has a standard RJ 45 plug After you connect the console port to the...

Page 12: ...l ready DTR No connect 8 Signal ground SG GND Note Because the console port of S2510 B bears no flow control you need to set Data flow control to none when using a superior terminal to manage S2510 B...

Page 13: ...y To use the optical port you need connect it to the SFP optical module and then to other Ethernet terminal devices through an optical fiber 3 3 3 Connecting Ethernet Electric Port S2510 B has 8 10 10...

Page 14: ...RXD1 Input 4 Sending the normal phase of the data TXD2 Output 5 Sending the paraphase of the data TXD2 Output 6 Receiving the paraphase of the data RXD1 Input 7 Receiving the normal phase of the data...

Page 15: ...on Manual 13 Check whether the connected power meets the power requirements of the switch Check whether the grounding line of S2510 B is correctly connected Check whether S2510 B is correctly connecte...

Page 16: ...the switch required tools and operation methods Caution When the power cable still connects the power supply do not touch it When you open the chassis of the switch you may use the following tools The...

Page 17: ...ed Otherwise the chassis is hard to install 4 2 Closing Chassis The section mainly describes how to put the chassis and close the chassis Do as follows 1 Following the directions shown on the above me...

Page 18: ...vironmental conditions and make sure that the switch is put at a working location with a temperature of 0 to 45 If the power supply of S2510 B provides power normally power indicator PWR is on or indi...

Page 19: ...en approval of the company any person or group cannot transcribe copy or change partial or all contents of this manual and must not broadcast it in any manner Trademark claims Trademarks product names...