background image

Instruction manual

Your animal imaging partner

Summary of Contents for Duo-Scan Axial

Page 1: ...Instruction manual Your animal imaging partner...

Page 2: ...y 4 Display layout 5 1 Operating instructions 6 1 1 Preliminary switch on 6 1 2 Power 6 1 3 Imaging display device connection 7 1 4 Scanning 7 2 Care maintenance 10 2 1 Power packs 10 2 2 Probe 11 Tec...

Page 3: ...ng ultrasound imaging equipment for veterinary and animal husbandry applications we realise the importance of equipment reliability and speed of response should service assistance be required Our engi...

Page 4: ...n Four hours continuous use from external rechargeable battery The unit is water resistant to IP65 see comments later in manual Easily cleaned all component parts can be wiped down to clean Operator s...

Page 5: ...t and gives a comparison of grey intensity for the ultrasound picture 3 The current function of the soft keys is displayed along the bottom of the screen The menu disappears after approximately 6 seco...

Page 6: ...To turn the scanner on press and hold the power button fig 2 until the scanner beeps The control panel LED fig 3 will illuminate green The probe will start to rotate If the imaging display device is c...

Page 7: ...isplay device be sure the connector is free from dirt Displays are connected to the user connector port If you are using a wireless monitor you do not need to connect it to the console If the monitor...

Page 8: ...ode 5 Range 22 cm Frequency 3 5 MHz Mode 6 Range 25 cm Frequency 3 5 MHz Note Probe stop should be used if scanner losses synchronisation The shorter ranges are for use in nearer imaging for improved...

Page 9: ...l display either Gain Power or Mode in the 2nd box To switch between gain power and mode press the Select button To adjust the Gain or Power values use the Up and Down keys on the front panel 1 4 3 Fr...

Page 10: ...roof and thus it should not be left wet 3 Some types of goggles are not waterproof and care should be taken to avoid submersion 4 The standalone charger battery charger and charging carry case are not...

Page 11: ...this may cause the window to burst Do not push against the probe window the sealing may be damaged or fluid may be forced out of the internal expansion tube If a window or its seal leaks then the pro...

Page 12: ...for the duration below This time will vary depending on the display option used Duo Scan Axial with power pack latched 4 hours Electrical connection to the power pack is through the gold pads on batte...

Page 13: ...ction in available capacity with resulting reduced run times After the battery has been exercised the full capacity returns A return to almost full capacity is achieved with a complete charge discharg...

Page 14: ...rding to the selected depth range User output User connector provides video output Composite NTSC video format for display headset Video review or Video printer accessories using adapter lead accessor...

Page 15: ...15 Accessories BUG BCF Universal Goggles Battery charger Carry bag Battery pack Remote Display Video splitter Protective carry case...

Page 16: ...y Ltd Unit 2 Quayside Business Park Mill Street Dundalk Co Louth Ireland T 353 0 42 932 0070 ireland bcftechnology com www bcftechnology com In North America BCF Technology USA Ltd LLC 2900 43rd Stree...