Microseparator™ Coolant Systems Transport, Installation, & Initial Startup
M000005_A - V Twin Ultra Transport & Installation 5.2-EN TM
56/78
18.12.3
Connecting the Coolant Supply Line
For the Pump Station, connect a transparent coolant
hose to the barbed fitting as shown in the
photograph at right. Route the hose through the hole
shown at
on page 53.
Connect the other end of
the coolant hose to the coolant valve connection as
specified by the generator manufacturer.
Figure 39 - Pump Station Coolant Supply Line
For the Pump Station Low Profile, connect a transparent coolant hose to
the location shown as
ConnectionsFigure 38 - Pump Station Connections
on page 53.
Connect
the other end of the coolant hose to the coolant valve connection as
specified by the generator manufacturer.
18.12.4
Connecting the Coolant Drain Line
Consult the generator manufacturer’s specifications and drain line fitting
location.
Connect the drain pipe to the drain fitting specified by the generator
manufacturer.
An open hole is provided to fit the DN100/4” drain pipe into the Machine
front section. A rubber gasket is supplied fitted to the open hole.
Remove the rubber gasket before inserting the pipe into the Machine and
follow these steps:
Remove the gasket from the hole on the side.
Apply liquid soap to the un-flanged pipe end and slide the pipe through
the gasket.
Pass the flanged end of the pipe through the hole shown at
on page 53
and fit the gasket to the open
hole.
Fit a DN100 90° elbow to the DN100 pipe so that it fits against the
opposite interior wall of the front section of the Machine.
Make sure that the drain line maintains a constant gradient of
approximately 2% (2cm/1m of pipe run) with minimal turns and without
restriction to diameter.
18.13
Electrical Connection
The machine has been preset to the voltage specified on the rating plate.
No electrical interconnect cable is supplied to the mains power with the
shipment.
Only qualified electricians or duly trained personnel under the instruction
and supervision of a qualified electrician may do any work on electrical
equipment and systems.