Microseparator™ Coolant Systems Transport, Installation, & Initial Startup
M000005_A - V Twin Ultra Transport & Installation 5.2-EN TM
45/78
18.3
Technical Data
The following table provides the major technical data.
Weight
Ready for operation
153 kg (336 lbs.)
Power Supply
Supply voltage
208/3/60 VAC/Ph/Hz OR
380/3/50 VAC/Ph/Hz
Power consumption
1.25 KVA
Fusing on site
10 A
Compressed Air
Minimum
4.1 bar (60 PSIG)
Maximum
6.8 bar (100 PSIG)
Setting value
4.8 bar (70 PSIG)
Compatible fluids
Domestic water
Pure water is not compatible
Coolants
Fully synthetic is recommended
OMA Interface
None required
Continuous Noise Level
≤ 70 dB(A)
Dimensions
D x W x H
1153mm x 533mm x 1289mm
(45.5” x 21” x 50.75”)
Weight
153 kg (336 lbs.)
Coolant Supply
To generator
Consult coolant system manual
To cooling tank
Min. 20 lpm
Figure 31 – Pump Station Technical Data