13 Technical Data
43
13
Technical Data
Salinity
1,5 g/l
3,3 g/l
Chlorine production
21 g/h
28 g/h
Max. Recommended pool size
T
Water
< 28
O
C
100 m
3
170 m
3
T
Water
> 28
O
C
80 m
3
110 m
3
Display
2.8“ TFT colour display
Operation
Software-based operation via 6 keys
Electronics
32bit microprocessor
Operational safety
Password protection for Service level
Language selection
German, English, French, Spanish, Italian
Salt content
1.5 g/l, 3,3 g/l – 100 g/l
Adjustment of cell output
0 – 100 %, adjustable in increments of 1 %
Reduced production with pool cover closed
Yes, via external signal from the pool cover, Reduction freely adjustable
Increased production
Boost function
Automatic cell cleaning
Polarity reversal, cycles adjustable from 1 to 999 minutes
Operating hour counter
Yes, can be viewed by the user
Flow, electrolysis cell
4 m
3
– 30 m
3
Flow monitoring
Gas sensor in the electrolysis cell
Paddle switch
Dimensions, electrolysis cell holder
310 x 63 mm
Cable, electrolysis cell
1.5 m
Max. pressure, electrolysis cell
3.5 bar
Cell service life
Typical 5,000 hours
Cell material
Titanium, coated with ruthenium/iridium
Permissible water temperature
1 °C – 45 °C
Temperature measurement
Measurement via LM35 sensor, stainless steel
Measuring range 0 – 100
O
C
Resolution 1
O
C
Calibration 1-point calibration
Measurement of the pH value (optional)
Measurement via combination electrode
Unidirectional control; bidirectional control optional
Measuring range pH 0 – 10 pH
Resolution pH 0.1 pH
Calibration pH 1- or 2-point calibration (pH 7 and pH10)
Redox measurement (optional)
Measurement via combination electrode
Measuring range Rx 0 – 1000 mV
Resolution Rx 1 – 3 mV
Calibration Rx 1-point calibration
Measurement inputs
pH and redox BNC
Temperature terminal
Alerts
Too little salt in the water
No flow through electrolysis cell
pH dosing (only if pH module is used)
pH too high/too low (only if pH module is used)
pH dosing alarm (only if pH module is used)
Switching outputs
3 x 110 – 230 V
4 x floating
Pump with variable speed control (3 x speed, 1 x common).
Electrical connection
110 – 240 V~, 50/60 Hz
Power consumption
Max. 150 W
Protection class, controller
IP 54
Weight, controller
approx. 2.8 kg
Dimensions, controller
237 x 300 x 152 mm (W x H x D)
Transport damage
Our devices and spare parts are always transported at user's risk. Prior to accepting the goods, the user must check that they are in perfect condition.
Transport damage must be entered on the forwarding agent's consignment note. BAYROL accepts no liability for transport damage.