10 Maintenance
41
Swimming pool
Oxidation on metallic parts of
the swimming pool
The oxidised elements and/or the swimming pool are not
adequately earthed.
Have the earthing checked by a specialist.
The oxidised elements are not made from stainless steel
of an appropriate quality.
Use elements made from stainless steel of an appropriate quality.
WIFI Modul
The correct password has been
entered for the WIFI network but
both LEDs are not lighting.
The module did not connect to the required network.
Changing the channel (router settings) may solve the problem.
Please consult an expert in the area of IT.
10
Maintenance
The maintenance schedule lists only the minimum maintenance requirement. The frequency at which maintenance is required depends on the
intensity of use.
The maintenance intervals are defined by the relevant, country-specific regulations! This means that maintenance intervals may be considerably
shorter than those given here. The relevant country-specific regulations and standards must be complied with.
NOTE!
Only the manufacturer's spare parts and sensors may be used. Failure to observe this will result in loss of warranty.
10.1
Cell cleaning
The Salt Relax POWER is equipped with a programmable automatic cell cleaning function. This function is based on cyclical reversal of the polarity of
the chlorine production cell. Reversing the polarity allows limescale crystals deposited on one side of the cell plates in operation to be removed
automatically. The procedure for setting this function is described in the menu "Service settings."
You can shorten the polarity cycles if you find that limescale deposits tend to form in your chlorine production cell. However, please note that a setting
of 200 minutes or less will greatly reduce the typical life of the chlorine production cell and void the warranty.
If, on the other hand, you find that your chlorine production cell remains clean even after extended periods of operation, you can extend the polarity
cycles, which increases the service life of the chlorine production cell.
If limescale deposits nevertheless form on the cell blades, you can remove the cell from the cell holder (it is imperative to close the bypass valves
before doing this. Caution! Water may emerge) and immerse it in a bath of BAYROL Decalcit. Clean the paddle flow switch at the same time, as it
may also have limescale deposits or soiling.
NOTE!
It is imperative to remove the cell from the cleaning bath as soon as the deposits have been dissolved. Leaving the cell in the solution
for longer will result in damage which is not covered by the warranty!
Never try to remove the deposits mechanically (e.g. with a brush or metal instruments). This may result in irreparable damage to the
cell.
10.2
General maintenance
Check the water values as listed in the table in the chapter Water chemistry.
Perform regular backwashing to maintain filter performance. Check the salt content after adding fresh water. If necessary, add salt to
compensate for the loss due to backwashing.
Clean the skimmer/overflow channel of your pool regularly.
Use your floor cleaner as usual.
From time to time, carry out a visual inspection of the system. In particular, examine all components for leakage and check the condition of
the chlorine production cell.
Replace the electrodes (pH and redox, if used) and the dosing hose of the pumps annually.
10.3
Cleaning
If necessary, clean the surface of the device with a soft, lint-free cloth. You can moisten it with a little water if required.
Never use aggressive cleaning agents.