4 Operating the Salt Relax POWER
27
4.5.5
Extra settings
Activation of the flow signal FL1 is defined in Extra settings.
To switch over, select Extra settings with
/
and confirm with
Setting of the flow signal:
Setting 0: The signal FL1 is only activated by the gas sensor of the cell
(the external flow switch is deactivated).
Setting 1: Signal FL1 is never activated.
Setting 2: Signal FL1 is only activated by the external flow switch (the gas
sensor of the cell is deactivated).
Setting 3: Signal FL1 is activated if either the gas flow sensor of the cell
OR the external flow switch trips.
If you attach an external flow switch (e.g. the paddle flow switch supplied)
to the screw terminals (see Connecting terminals), please set the value 3
(default setting).
Never set values greater than 3 in this menu.
If necessary, change the setting with
/
and confirm with
.
4.5.6
Reset settings
In Reset settings, all settings made can be reset to the as-delivered status.
To do this, select Reset settings with
/
and confirm with
If you are sure you wish to restore the factory settings, answer the
confirmation prompt with
If you wish to retain the settings, exit the confirmation prompt with
4.5.7
Reset counters
In Reset counters, the operating hour counter of the chlorine production cell can be reset.
To access the settings, select Reset counters with
/
and confirm with
In the next screen, select Electrolysis with
/
and confirm with
If you are sure you wish to restore the factory settings, answer the
confirmation prompt with
If you wish to retain the settings, exit the confirmation prompt with
Connection
The menu item Connection is without function.
No setting may be made here.