Set the Remote Annex 4000 to Test Mode.
Pressing the Test button within 3 seconds of
powering up puts the Remote Annex 4000 into
test mode. To enter test mode when the Annex is
already running, hold down the Test button until
the Power LED blinks rapidly, then release the
Test
button and press it again within 3 seconds.
This second method resets the Remote Annex, so
warn users before you do it.
Press the Test button located on the Remote Annex 4000 front
panel. The Test LED lights when the unit enters Test Mode (see
Figure 2-19).
Figure 2-16. Setting the Remote Annex 4000 to Test Mode
Next, the Remote Annex 4000 runs diagnostic tests, causing the
Active
LED to flash. If the diagnostics complete successfully, the
Unit
, Net, and Attn LEDs light. If a terminal is connected to the
console port, the ROM Monitor prompt appears on the terminal.
STATUS
POWER
UNIT
NET
ATTN
LOAD
ACTIVE
1
2
3
4
5
6
7
8
TEST
Test Button
Summary of Contents for Remote Annex 4000
Page 1: ...Part No 166 024 151 Rev C March 1996 Hardware Installation Guide Remote Annex 4000 ...
Page 4: ...Remote Annex 4000 Hardware Installation Guide Revision Level History iv ...
Page 8: ...Remote Annex 4000 Hardware Installation Guide Contents viii ...
Page 10: ...Remote Annex 4000 Hardware Installation Guide Figures x ...
Page 12: ...Remote Annex 4000 Hardware Installation Guide Tables xii ...
Page 16: ...Remote Annex 4000 Hardware Installation Guide Preface xvi ...
Page 71: ...2 33 Remote Annex 4000 Hardware Installation Guide Chapter 2 Installing the Remote Annex 4000 ...
Page 72: ...Remote Annex 4000 Hardware Installation Guide Chapter 2 Installing the Remote Annex 4000 2 34 ...