Remote Annex 2000 Hardware Installation Guide
Chapter 4 Troubleshooting Procedures
4-10
Activity TE2:
Hardware Failure
The ROM diagnostics detected an Remote Annex 2000 hardware
problem requiring service. The status LEDs flash the specific error
number. Call technical support.
Activity TE3:
Network Test Failure
The Ethernet interface did not pass a simple transceiver loopback test.
First, verify that the Ethernet port is either connected to an Ethernet
transceiver or has a loopback plug installed. If the test still fails, typing
q
on the console accesses the ROM Monitor prompt. See
3-22 for more information.
Activity TE4:
Network Test was
Aborted or the net
Command Failed
The Ethernet loopback test failed and the operator has typed q to
access the ROM Monitor prompt.
Activity TE7: Booted
Wrong Image
The Remote Annex 2000 has just loaded an inappropriate image. Clear
this error by pressing the
button. The Remote Annex 2000
loads inappropriate images if one of the following operator errors
occurs:
❑
Configuring the Remote Annex 2000 with an incorrect file
name, or renaming or copying the image file to the wrong
name.
❑
Supplying the wrong name to the boot command.
Boot Failures
The procedures for troubleshooting a power-up failure
established that:
❑
The hardware is functional.
❑
The Ethernet interface is functional.
❑
The Remote Annex 2000 can communicate with the Ethernet.
Reset
Summary of Contents for Remote Annex 2000
Page 1: ...Part No 166 024 150 Rev C1 August 1996 Hardware Installation Guide Remote Annex 2000 ...
Page 4: ...Remote Annex 2000 Hardware Installation Guide Revision Level History iv ...
Page 8: ...Remote Annex 2000 Hardware Installation Guide Figures x ...
Page 10: ...Remote Annex 2000 Hardware Installation Guide Tables xii ...
Page 14: ...Remote Annex 2000 Hardware Installation Guide Preface xvi ...