Installing the outdoor unit on its wall bracket
For wall mounting, fit the wall support kit and the anti-vibration studs
available separately: package EH95.
The data plate must be accessible at all times.
1. Mount the wall bracket with the horizontal plane at least 200 mm
above the ground.
2. Fit anti-vibration studs under the outdoor unit.
3. Mount the outdoor unit on its wall bracket.
The mounting screws are provided in the package EH95.
Connecting the condensate recovery pipe
1. Insert the condensate discharge union in the special hole.
2. Turn the union to secure it in its housing.
3. Connect the pipe on the union.
6.3
Water connections
Warning
The domestic hot water circuits must be rinsed before the
hydraulic connections are made.
If flushing has to be done using an aggressive product, neutralise
the rinsing water before disposing of it in the waste water network.
Important
Using hoses which are too short or too rigid encourages the
transmission of vibrations and could generate noises.