37
INST
ALLER Section
(en)
7219620.01 (1-04/15)
P19
Manufacturer information
07
P20
Pump overrun time in DHW mode
(seconds)
30
P21
Anti-legionellosis function (°C)
00…54
= Disabled -
55…67
= Enabled
(set the desired temperature value)
00
P22
Manufacturer information
00
P23
Maximum DHW setpoint temperature (ACS)
60
P24
Manufacturer information
35
P25
No water safety device
00
P26..P31
Manufacturer information
--
P32..P41
Diagnostics (See SERVICE Instructions)
--
P67
Open Therm (OT) settings
(
See SERVICE Instructions
)
00
= Plug & Play
00
14.1 ADJUSTING MAXIMUM HEATING POWER
The maximum heating power of the boiler can be reduced to suit the requirements of the heating system it serves. A table showing
parameter
P13
values according to the desired maximum power model is shown below for each single boiler
To access and edit parameter
P13
values, proceed as described in the PARAMETER SETTINGS section.
Boiler model - PARAMETER P13 (%) / Heating output (kW)
kW
1.12
1.24
1.28
24
28
33
40
2
0
3
10
3,5
15
0
0
4
20
2
0
2
0
5
30
7
4
7
4
0
6
40
12
8
12
8
4
0
7
50
17
13
17
13
7
3
8
60
22
17
22
17
11
6
9
70
27
21
27
21
14
9
10
80
32
25
32
25
18
11
12
100
41
33
41
33
25
17
14
51
42
51
42
32
23
16
61
50
61
50
39
29
18
71
58
71
58
46
34
20
80
67
80
67
54
40
22
90
75
75
61
46
24
100
83
86
68
51
26
92
75
57
28
100
80
63
30
69
32
74
33
77
Summary of Contents for LUNA DUO-TEC+
Page 112: ...7219620 01 1 04 15 112 S E C T I O N A...
Page 118: ...7219620 01 1 04 15 118 S E C T I O N C 7218789 01 53 5 41 5...
Page 119: ...119 S E C T I O N C 7219620 01 1 04 15 53 5 41 5 A 168 5 53 5 41 5 A 168 5...
Page 120: ...7219620 01 1 04 15 120 S E C T I O N D 25 mm...
Page 123: ...123 S E C T I O N F 7219620 01 1 04 15...
Page 124: ...7219620 01 1 04 15 124 S E C T I O N G...
Page 126: ...7219620 01 1 04 15 126...
Page 127: ...127 7219620 01 1 04 15...