![Baxi ECOGEN 24/1.0 Installation & Servicing Instructions Manual Download Page 62](http://html1.mh-extra.com/html/baxi/ecogen-24-1-0/ecogen-24-1-0_installation-and-servicing-instructions-manual_2711788062.webp)
2. Remove the screws securing the thermostat to the mounting plate on the flow pipe.
3. Fit new thermostat and reassemble in reverse order.
14.13 Ambient Sensor
1. Pull the connectors off the sensor.
2. Remove the screw.
3. Fit the new sensor and reassemble in the reverse order ensure the gas valve electrical connections is securely home.
14.14 Water Flow Sensor (
)
1. Drain the primary circuit (see
2. Carefully remove the 3 wire connector noting orientation there is a small latch.
To remove just the sensor element only (recommended):
a) Remove the locking ring by twisting anti clockwise.
b) Withdraw the sensor element.
c) Reassemble in the reverse order there is a key way to ensure the sensor is lined up with the body correctly.
d) Reconnect the 3 wire connector (
).
To remove just the sensor body:
a) Disconnect the four wires on the temperature sensors (
).
b) Remove the three pipe clips. One near the heat exchanger and two on the body flow sensor (
).
c) Carefully withdraw the assembly from the heat exchanger and the rear central heating flow pipe.
d) Remove the sensor body from the flow pipe.
e) Reassemble in the reverse order being careful not to damage the O rings.
Ensure the sensor body is fitted in the correct orientation with the arrow pointing to the back of the appliance (
).
f) Ensure the 3 wire connector is fitted the correct way round (
).
Summary of Contents for ECOGEN 24/1.0
Page 69: ...Fig 77 Fig 78 Fig 79 page 69 16 0 Schematic Wiring 16 1 Burner Control Units BCU Connections...
Page 70: ...page 70 16 2 Milligrid 24 way Connector...
Page 71: ...page 71 16 3 14 way Connector...
Page 72: ...page 72 16 4 Engine Circuit...
Page 73: ...page 73 16 5 Power Monitoring 24Vdc Power Supply...
Page 74: ...page 74 16 6 External Connections External Wiring...
Page 85: ...page 87...
Page 86: ...page 88...
Page 87: ...page 89 Section P...
Page 88: ...page 90...
Page 89: ...page 91 Section Q Engine developing less than 950W after 15 minutes running at maximum rate...
Page 91: ...page 93 page 94 page 95 page 96 MICRO CHP SYSTEM COMMISSIONING CHECKLIST...
Page 92: ...page 97...