USER Section

  (en)

7.  ROUTINE MAINTENANCE INSTRUCTIONS

To keep the boiler efficient and safe, have it checked by the Authorized Service Technician at the end of every operating period.

Careful servicing ensures economical operation of the system.

  

 

  

  

8.  CHECK LIST

If a fault develops, or is suspected, call your Service Technician as soon as possible.

  

Go through the following check list before you make contact.

  

a)

 Is the electricity supply on?

b)

 Is the display ON and the symbols    

 are displayed?

c)

 Is the symbol   displayed?

d)

 Is the gas supply on?

e)

 Is the main water supply turned on?

f)

 Is the system pressure correct?

g)

 Are the boiler temperature controls set high enough?

h)

 Is the room thermostat (if fitted) set high enough?

i)

 Are the radiator valves open?

  

 

  

9.  IMPORTANT NOTES

9.1  BOILER LOCATION

Always ensure the following clearances are available for servicing around the boiler:

Top: 9.84 in (250.00 mm) for DUO-TEC COMPACT and 8.66 in (220.00 mm) for LUNA DUO-TEC, Bottom: 9.84 in (250.00 mm), 

each side: 1.77 in (45.00 mm), Front: 17.72 in (450.00 mm)

If the boiler is installed in a cupbord or compartment, do not store any other articles in the cupboard containing the boiler and never 

place any clothing or combustible material on or near the boiler or flue.

  

 

  

9.2  FLUE TERMINAL

The terminal on the outside wall must not be allowed to be obstructed. If it is damaged, in any way, turn the boiler off and contact 

your Service Technician.

In cold weather, steam may be emitted from the terminal. This is quite normal.

  

  

  

9.3  POWER FAILURE

In the event of an electrical supply failure the boiler will not operate. When the supply is restored, the boiler will return to normal 

operation. Remember to reset the clock when the supply is restored.

If the mains water supply fails, there will be no hot water from the taps. The boiler will continue to provide central heating.

  

 

  

9.4  ADDITIONAL BATHROOM FITTINGS

Any equipment such as mixing valves, showers, bidets etc. must be designed to operate at mains water pressure. Contact your 

local Water Authority for advice when considering purchasing such items.

  

  

  

9.5 CLEANING

Use only a damp cloth and mild detergent to clean the boiler outer casing. Do not use abrasive cleaners.

  

 

  

9.6 SERVICING

To  maintain  efficient  and  safe  operation  of  your  boiler,  routine  annual  servicing  is  essential  (see  Installation  and  Servicing 

Instructions).

  

 

  

9.7  GAS LEAK

If a fault or gas leak is suspected, turn off the gas supply. Do not touch any electrical switches, do not smoke and extinguish all 

open flames. Contact your local Gas Supplier from a neighbors phone.

  

  

  

9.8  ELECTRICAL SUPPLY

The boiler requires a 120 V 60 Hz supply.

  

THE APPLIANCE MUST BE GROUNDED AND ON A DEDICATED CIRCUIT.

  

 

  

Summary of Contents for DUO-TEC COMPACT 30 GA

Page 1: ...GA LUNA DUO TEC 40 GA LUNA DUO TEC 1 33 GA en CONDENSING GAS FIRED WALL MOUNTED COMBINATION BOILER Instructions for the end user fr CHAUDI RE MURALE GAZ CONDENSATION DEUX SERVICES Notice d installatio...

Page 2: ...lystyrene etc within children s reach as they are a potential source of danger CONTENT SPECIAL ATTENTION BOXES 3 1 DESCRIPTION 4 2 USER CONTROLS 4 3 OPERATING THE BOILER 5 3 1 TEMPERATURE CONTROL 5 3...

Page 3: ...o not turn off or disconnect the electrical supply to the pump Instead shut off the gas supply at a location external to the appliance Do not use this boiler if any part has been under water Immediate...

Page 4: ...pors and liquids in the vicinity of this or any other appliance WHAT TO DO IF YOU SMELL GAS Do not try to light any appliance Do not touch any electrical switch do not use any phone in your building I...

Page 5: ...vent make up water FREEZE PROTECTION FLUIDS CAUTION NEVER use automotive or standard glycol antifreeze Even ethylene glycol made for hydronic systems Use only inhibited propylene glycol solutions whic...

Page 6: ...ety trip control performed via a temperature sensor Press the RESET R button for at least 2 seconds If the this fault persists call an authorized SERVICE technician 128 Loss of flame Press the RESET R...

Page 7: ...operation is 7 26 psi 0 50 bar If the pressure falls below 7 26 psi 0 50 bar this may indicate a leak on the central heating system The system must be re pressurised by your Service Engineer 5 SHUTTI...

Page 8: ...the boiler or flue 9 2 FLUE TERMINAL The terminal on the outside wall must not be allowed to be obstructed If it is damaged in any way turn the boiler off and contact your Service Technician In cold...

Page 9: ...contact your qualified service technician to inspect the unit and the vent combustion air system Check Pressure Gauge ensure the pressure reading on the pressure gauge does not exceed 25 5 psi 1 8 Ba...

Page 10: ...sposal This discharge line must be installed by a qualified service technician or heating plumbing installer in accordance with the Boiler installation manual The discharge line must be terminated so...

Page 11: ...fants ce sont des sources potentielles de danger SOMMAIRE ENCADR S POUR ATTIRER L ATTENTION 12 1 DESCRIPTION 13 3 MISE EN SERVICE DE LA CHAUDI RE 14 3 1 R GLAGE DE LA TEMP RATURE 14 3 2 MENU D INFORMA...

Page 12: ...on lectrique la pompe Au lieu de cela couper l alimentation en gaz un emplacement externe l appareil Ne pas utiliser cette chaudi re si une ou plusieurs parties ont t sous l eau Contacter imm diatemen...

Page 13: ...l ou de tout autre appareil QUE FAIRE EN CAS D ODEUR DE GAZ Ne tenter pas d allumer aucun appareil N actionner aucun interrupteur lectrique ne pas utiliser les t l phones situ s dans le b timent Appel...

Page 14: ...UIDES DE PROTECTION CONTRE LE GEL ATTENTION Ne JAMAIS utiliser de glycol automobile de glycol antigel standard ou m me de l thyl ne glycol pr vu pour des syst mes hydroniques N utiliser que des soluti...

Page 15: ...un capteur de temp rature Appuyer sur le bouton RESET R pendant au moins 2 secondes Si cette erreur persiste contacter un Service d assistance technique agr 128 Arr t de la flamme Appuyer sur le bouto...

Page 16: ...r cela pourrait indiquer une fuite dans l installation de chauffage central Le syst me doit tre repressuris par un technicien d entretien 5 POUR TEINDRE LA CHAUDI RE Pour teindre la chaudi re d branch...

Page 17: ...combustibles sur ou pr s de la chaudi re ou du conduit de fum es 9 2 TERMINAL DE FUM E Le terminal situ l ext rieur du mur ne doit jamais tre obstru S il est endommag de quelque fa on que ce soit tein...

Page 18: ...entretien qualifi pour examiner l unit et le syst me d air comburant ventilation V rifier le manom tre s assurer que la valeur de pression indiqu e sur le manom tre ne d passe pas 25 5 psi 1 8 Bar EN...

Page 19: ...nch la bouche de la soupape de d charge et orient vers un lieu d vacuation s r Cet conduit d vacuation doit tre install par un technicien d entretien qualifi ou par un installateur de plomberie chauff...

Page 20: ...Baxi N A 2201 Dwyer Ave Utica NY 13501 1 844 4 BAXINA www baxiboilers com 7703471 01 1 03 18...

Reviews: