1.0 Warnings
3
1.1
Safe Installation
1. The appliance is suitable for installation only in
G.B. and I.E. and should be installed in
accordance with the rules in force. For Ireland
install in accordance with I.S.813
“I
NSTALLATION
OF
G
AS
A
PPLIANCES
”
. The installation must be
carried out by a CORGI Registered Installer or
other registered competent person and be in
accordance with the relevant requirements of
G
AS
S
AFETY
(Installation and Use)
R
EGULATIONS
most
recent edition, the
B
UILDING
R
EGULATIONS
issued
by the Department of the Environment,
B
UILDING
S
TANDARDS
(Scotland) (Consolidation)
R
EGULATIONS
issued by the Scottish Development
Department and the
L
OCAL
B
UILDING
R
EGULATIONS
.
Where no specific instructions are
given, reference should be made to the relevant
BRITISH STANDARD CODES OF PRACTICE
and INSTALLATION SPECIFICATIONS.
2.
This appliance must be installed in
accordance with the manufacturer’s
instructions and the rules in force, and only
used in a suitably ventilated location.
3.
Read the instructions before installing or
using this appliance.
4. Any purpose provided ventilation should be
checked periodically to ensure that it is free from
obstruction.
IMPORTANT
- The addition of anything that
may interfere with the normal operation of the
appliance without the express written
permission of Baxi UK Limited could invalidate
the appliance warranty and infringe the
G
AS
S
AFETY
(Installation and Use)
R
EGULATIONS
.
1.2
In case of gas leaks
1. If a gas leak is found or suspected, turn off the
gas supply at the meter immediately and at the
isolating valve on the boiler if possible. Contact
your Installer or Transco (under 'Gas' in the
phone directory).
1.3
Servicing your Appliance
1. For reasons of safety and economy your
appliance should be serviced annually. Servicing
must be performed by a competent person. Your
Installer or British Gas Service will be able to
advise you.
1.4
Electricity Supply
1.
THIS APPLIANCE MUST BE EARTHED.
2. A standard 230V ~ 50Hz supply is required.
The appliance must be protected by a 3 amp
fuse.
Never Hang Flammable Items Over The
Appliance
STANDARD
B.S. 6891
B.S. 5440: Pt 1
B.S. 5440: Pt 2
B.S. 5546
B.S. 7074
B.S. 5449
B.S. 6798
SCOPE
Gas Installation.
Flues.
Air Supply.
Installation of hot water supplies
for domestic purposes.
Expansion vessels and ancillary
equipment for sealed water systems.
Forced circulation hot water systems.
Installation of gas fired hot water
boilers.
IN AN EMERGENCY
If a water or gas leak occurs or is suspected, the boiler can be
isolated at the inlet valves as follows;
1. Turn off the electrical supply and turn the selector switch on
the facia box to the OFF position.
2. Using a suitable open ended spanner or screwdriver turn the
square on the gas tap to the left to isolate the gas supply at the
boiler (Fig. 1).
3. The isolating valves are positioned under the boiler and can be
closed by turning their taps to the right towards the wall (Fig. 2).
4. Call your Service Engineer as soon as possible.
“Benchmark” Installation, Commissioning and Service
Record Log Book
Please ensure that your installer has completed the Installation
and Commissioning sections of the Log Book and hands the Log
Book over. The details of the Log Book will be required in the
event of any warranty work. Keep the Log Book in a safe place
and ensure that the relevant sections are completed at each
subsequent regular service visit.
Gas Tap
Heating Flow and
Heating Return
Isolating Valves
Fig. 1
Fig. 2
All CORGI registered installers carry a CORGI identification card
and have a registration number. Both should be recorded in your
boiler Log Book. You can check your installer is registered by
telephoning 01256 372300 or writing to:-
1 Elmwood,
Chineham Business Park,
Crockford Lane,
Basingstoke RG24 8WG