Installation
50
Mono Power Unit BUM 62, 63, 64
5.94005.12
Baumüller Nürnberg GmbH
y
3-phase line reactors for 400 V supply voltage, T
A
= 55°C max.,U
k
= 4 % / 4.8 %,
U
N
= 400 V, 50/60 Hz, with flat termination IP 00
y
3-phase line reactors for 500 V supply voltage, T
A
= 55°C max., IP 00
U
k
= 4 % / 4.8 %, U
N
420 ... 500 V, 50/60 Hz, with flat termination IP 00
y
EMC package
on requirement available:
-
EMC filter
-
shielded cable
-
connection parts
Line
reactor
DR3-40-4l
Type
DC
current
A
a
mm
b
mm
c
mm
d
mm
e
mm
f x g
mm
Flat
termination
∅
mm x mm
Weight
kg
Losses
W
Part
no.
1900 ..
- 0 200
200
310
170
255
280
106
11 x 18
40 x 4
∅
14
28,0
160
-7474
- 0 400
400
310
220
260
280
131
11 x 18
40 x 4
∅
14
45,0
180
-7476
Line
reactor
DR3-40-4l
Type
DC
current
A
a
mm
b
mm
c
mm
d
mm
e
mm
f x g
mm
Flat
termination
∅
mm x mm
Weight
kg
Losses
W
Part
no.
1900 ..
- 0 200
200
270
170
230
200
102
10 x 18
30 x 4
∅
11
27,5
160
-7487
- 0 400
400
360
230
315
300
150
9 x 14
40 x 5
∅
14
73,0
225
-7489
Summary of Contents for BUM 62
Page 1: ...E 5 94005 12 Manual Mono Power Unit BUM 62 63 64 ...
Page 8: ...Safety Notes 8 Mono Power Unit BUM 62 63 64 5 94005 12 Baumüller Nürnberg GmbH ...
Page 16: ...Transportation Unpacking 16 Mono Power Unit BUM 62 63 64 5 94005 12 Baumüller Nürnberg GmbH ...
Page 28: ...Installation 28 Mono Power Unit BUM 62 63 64 5 94005 12 Baumüller Nürnberg GmbH ...
Page 62: ...Commissioning 62 Mono Power Unit BUM 62 63 64 5 94005 12 Baumüller Nürnberg GmbH ...
Page 66: ...Maintenance 66 Mono Power Unit BUM 62 63 64 5 94005 12 Baumüller Nürnberg GmbH ...
Page 73: ......