Overheat heat sink monitoring function
The temperature of the heat sink is monitored.
A linear thermal sensor is located on the heat sink the measured value of which is passed on to the
controller. This means the controller is responsible for the temperature monitoring (refer to the
controller description) which must be set according to the technical data in the controller description.
The message ”Power part on the motor side ready” is cleared.
y
Internal auxiliary voltage monitoring function
The voltage which is used to trigger the power transistors, is monitored.
If there is no internal auxiliary voltage, a message is generated. This message is transmitted to the
controller. The message ”Power part on the motor side ready” is cleared.
y
Safety relay (option)
The switching state of the safety relay is monitored.
For further information on the safety relay please refer to ”Messages via relay contacts” page 61.
w
WARNING
The highest temperature allowed for the heat sink is 90 °C - higher temperatures may destroy the
unit .
Adjust the controller in such a way, that ”Power part on the motor side ready” will be cleared by the
controller, when the heat sink reaches a temperature of 85 - 90 °C.
Summary of Contents for BUM 62 T
Page 1: ...E 5 99009 03 Manual BUM 62 T Mono Power Unit ...
Page 6: ...6 Mono Power Unit BUM 62 T 5 99009 03 Baumüller Nürnberg GmbH ...
Page 10: ...Safety notes 10 Mono Power Unit BUM 62 T 5 99009 03 Baumüller Nürnberg GmbH ...
Page 18: ...Transportation Unpacking 18 Mono Power Unit BUM 62 T 5 99009 03 Baumüller Nürnberg GmbH ...
Page 22: ...Assembly 22 Mono Power Unit BUM 62 T 5 99009 03 Baumüller Nürnberg GmbH ...
Page 48: ...Installation 48 Mono Power Unit BUM 62 T 5 99009 03 Baumüller Nürnberg GmbH ...
Page 62: ...Commissioning 62 Mono Power Unit BUM 62 T 5 99009 03 Baumüller Nürnberg GmbH ...
Page 66: ...Maintenance 66 Mono Power Unit BUM 62 T 5 99009 03 Baumüller Nürnberg GmbH ...
Page 73: ......