Technical data
Mono Power Unit BUM 62 T
13
Baumüller Nürnberg GmbH
5.99009.03
3
T
ECHNICAL
DATA
3.1
Table of technical data
BUM 62 T - 100 / 130 - ...
Connection voltage (mains)
1)
3 x 400 V
AC
±15% 50 Hz
3 x 460 V
AC
+10% -25% 60 Hz
Supply voltage
2)
+ 24 V
DC
-10% / +20 % (72W)
Continuous input power
max. 50 kVA
Rated DC link voltage
3)
540 V
DC
DC link capacity (internal)
1700
µ
F
DC link capacity (external)
max. 500
µ
F
Cycle time for connect the unit in circuit again
(without additional DC link capacitors)
≥
3 min
Output voltage
4)
3 x 0 V
AC
... 3 x (conn. volt. -30 V)
Output frequency
5)
0 Hz. ...300 Hz
Continuous output power
at 4 kHz
10)
max. 62 kVA
Continuous output power
at 8 kHz
10)
max. 50 kVA
Continuous motor power
at 4 kHz
10)
max. 43 kW
Continuous motor power
at 8 kHz
10)
max. 35 kW
Rated output current
6) 7) 8)
at 4 kHz
10)
100 A
Rated output current
6) 7) 8)
at 8 kHz
10)
75 A
Peak output current
6) 7) 9)
at 4 kHz
10)
130 A
Peak output current
6) 7) 9)
at 8 kHz
10)
97 A
Connection power DC link connection
36 kW
External chopper current
max. 73 A
Internal chopper resistor
-
External chopper resistor
≥
11
Ω
Application threshold of regenerative resistor
750 V
Ambient temperature range (operation)
11)
min. 0 °C .... max. 55 °C
40 °C (nominal temperature)
Power loss
3)
Connect. (mains)
Supply
1400 W
max. 72 W
Type of protection
IP 20
Installation height
12)
max. 1000 m a.m.s.l.
relative humidity
15 % ... 85 % no condensation.
Temperature range for transport
- 30 °C ... + 70 °C
Temperature range for storage
- 30 °C ... + 70 °C
Dimensions (W x H x D)
264 x 560 x 280 mm
Weight without controller
30 kg
Summary of Contents for BUM 62 T
Page 1: ...E 5 99009 03 Manual BUM 62 T Mono Power Unit ...
Page 6: ...6 Mono Power Unit BUM 62 T 5 99009 03 Baumüller Nürnberg GmbH ...
Page 10: ...Safety notes 10 Mono Power Unit BUM 62 T 5 99009 03 Baumüller Nürnberg GmbH ...
Page 18: ...Transportation Unpacking 18 Mono Power Unit BUM 62 T 5 99009 03 Baumüller Nürnberg GmbH ...
Page 22: ...Assembly 22 Mono Power Unit BUM 62 T 5 99009 03 Baumüller Nürnberg GmbH ...
Page 48: ...Installation 48 Mono Power Unit BUM 62 T 5 99009 03 Baumüller Nürnberg GmbH ...
Page 62: ...Commissioning 62 Mono Power Unit BUM 62 T 5 99009 03 Baumüller Nürnberg GmbH ...
Page 66: ...Maintenance 66 Mono Power Unit BUM 62 T 5 99009 03 Baumüller Nürnberg GmbH ...
Page 73: ......