Connector Assignment Interface X1
Operation Manual
Safety Module for b maXX 5000
BM5-O-SAF-002/3
Document no.: 5.11016.03
Baumüller Nürnberg GmbH
90
11.1
Figure 45:
Representation SAF-module-pin assignment (option Daisy Chain)
11.1.1 Standard Terminal Configuration BM5-O-SAF-002-000-000
Standard configuration: signal names and meaning
Terminal no.
Assignment
Signal name
1
+24V2
+24V group2
2
STO_IN_2A
STO input A group2
3
CHAIN_IN_2A
Daisy-Chain input A group2
4
DIG1_IN_2A
input 1 A group2
5
DIG2_IN_2A
input 2 A group2
6
CHAIN_OUT_2A
Daisy-Chain output A group2
7
DIG3_IN_2A
input 3 A group2
8
CLK_OUT_2A
cycle output A group2
9
DIG_OUT_2A
output A group2
10
DIG_OUT_1A
output A group1
11
CLK_OUT_1A
cycle output A group1
12
DIG3_IN_1A
input 3 A group1
13
CHAIN_OUT_1A
Daisy-Chain output A group1
14
DIG2_IN_1A
input 2 A group1
Summary of Contents for BM5-O-SAF-002