49
Operation Manual
Safety Module for b maXX 5000
BM5-O-SAF-002/3
Document no.: 5.11016.03
8
D
ESCRIPTION
OF
THE
R
ESET
-
M
ODULE
This chapter describes the SAF-100 (Reset-Module) with its function and explains the
type code on the module.
8.1
General
In order to operate the axis unit of the series b maXX 5000 the slot A of the device must
be equipped with a module (also see 5.09021, instruction handbook b maXX 5000). In
case the device was previously equipped with a higher safety level, the parameter
storage of the controller must be reset before with the Reset Module (BM5-O-SAF-100)
or with a reset command (see
Resetting of the safety level by the controller
53).
8.2
Compatibility list
The Reset-Module (BM5-O-SAF-100) can only be used in the combination with
controllers of the type b maXX 5000, which where released by Baumüller Nürnberg
GmbH.
8.3
Operating mode of the Reset-Module (BM5-O-SAF-100)
In order to reset the module ID of the controller the slot A of the device must be equipped
with a Reset-Module. After switching on the voltage supply of the controller the ID of the
previously equipped modules is deleted.
After 15 seconds the voltage supply can be switched off and the slot A can be equipped
with the requested Safety Module.
An operation of the controller with the Reset-Module is not possible, because the module
does not provide supply for the controller’s drivers.