Description of the b maXX safe PLC module
Operation Manual
b maXX safe PLC
BMC-M-SAF-02
Document no.: 5.07020.04
37
7
7.4
Properties of the standard PLC
m
32-Bit RISC CPU 667 MHz
m
Program memory (Flash, 16-bit length) for saving the boot project 15 MB
m
Program memory (SDRAM, 32-bit length) 14 MB for executable program code
n
max. 1 750 000 instruction list lines (LD/ST instructions on the global version)
n
type 525 000 instruction list (typical IL instructions on structures and instance vari-
ables)
m
Approx. 9 MB memory (SDRAM) for debugging and logic analyzer functions
m
Memory for remanent data 100 KB NOVRAM
m
FDisk memory (for storing cam disks and configuration data): 22 MB
m
IEC data memory (SDRAM) of 1.75 MB expandable up to approx. 8.75 MB.
m
Cycle time approx. 25 µs per 1000 lines of instruction list (IL) for standard PLC
m
RS232 serial programming interface, visually separated from the b maXX safe PLC
m
Alternative programming interface via system components ethernet connection.
m
RS485 serial terminal interface, visually separated from the b maXX safe PLC
m
up to 5 additional modules (system components) can be addressed:
n
additional EtherCAT masters
n
additional CANopen masters
n
additional ethernet connections
n
additional ethernet connections with CANopen master
m
Motion control support
m
Power consumption of approx. 5 W
7.5
Properties of the safety PLC
The 32-bit RISC-CPU 667 MHz of the standard PLC is used jointly with the BMC-M-SAF-
02 for safety programming.
A 32-bit RISC-CPU with 400 MHz is also used.
m
Program memory of 1 MB for the executable program code of the safety application
which has been created with ProSafety.
m
With the dual-channel solution, the IEC program code is translated via the ProSafety
programming user interface with two different compilers; the output of compiler 1 is ex-
ecuted on channel 1, while the output of compiler 2 is executed on channel 2 (1 MB of
executable program code each).
m
IEC data memory (SDRAM) 256 KB
Programming interface via system components ethernet connection.
m
Safety PLC file system Flash 6 MB in total, of which:
n
1 MB of program memory per channel,
n
100 KB of configuration data,
n
750 KB of configuration data stacks,
n
2 MB reloadable stack area