Description of the Software Modules and Parameters
Parameter manual
b maXX
BM5800
Document No.: 5.16029.03
77
3
130.37
Udc threshold for mains failure
Absolute threshold for the mains failure detection.
As soon as the DC link voltage falls below this threshold, this is regarded as mains failure.
130.38
Udc hysteresis for mains failure
Hysteresis for the mains failure detection by means of the DC link voltage.
130.40
Operation time
Operating time of the power unit of an axis. Synchronizes the IGBTs; then this value is
incremented.
130.41
Instantaneous PWM frequency
Display parameter of the instantaneous (operating) PWM frequency.
The instantaneous PWM frequency deviates from the set PWM frequency
the safety function of the PU temperature model "PWM reduction" has responded (warn-
ing 216 is triggered). In this case the PWM frequency referring to the set PWM frequency
(
) is halved.
The corresponding instantaneous (operating) cycle time of the current controller is dis-
played in parameter
Of importance for devices, which support the PU temperature model, only (see status PU
temperature model
).
14
0: Input terminal channel 2 is powered with 24 V
1: No 24 V power supply at input terminal of channel 2
15
0: Input terminal channel 1 is powered with 24 V
1: No 24 V power supply at input terminal of channel 1
Bit no.
Meaning