Error messages and troubleshooting
Parameter manual
b maXX
BM5800
Document No.: 5.16029.03
731
4
4.3.2
LED assignment wit 2 LEDs (1 column)
4.4
Error handling
The entire error handling refers always to a single or double axis unit.
Error messages, which can also be considered error lists, are the basis of the error han-
dling.
4.4.1
Error reset
If the red error LED is illuminated, at least one error of a single or double axis unit is pres-
ent.
Error reset cause all error messages to be reset. Individual resetting of errors is not pos-
sible. A reset causes deletion of the errors, if deletion was possible on account of the error
circumstances.
Errors can be reset by setting bit 7 in control word.
For further information on the subject of error reset, see "Instruction Manual
b maXX
5800".
Col-
umn
LED
Color / flash code
Meaning
Axis
1
H11
green blinking
Power on and pulse enable at least one
axis or SE
1 to 7
green permanent
lighting
Power on and pulse enable at all con-
figured axes
orange
Power on – no pulse enable
green flashing
Download active
1
H12
red permanent light-
ing
Error at least one axis or SE
1 to 7
Alternative:
All axes have an error
red blinking slow
Warning at least one axis or SE
Alternative:
At least one axis has an error
red blinking fast
Torque limit at least one axis or SE
NOTE!
The device is shipped with predefined error reactions. With regard to the error mes-
sages identified with "depending on the setting" in the "Reaction" column, the de-
vice's error reaction can be adjusted. Errors that, due to safety reasons, have an
immediate pulse inhibit as a consequence, may not be changed.