Description of the Software Modules and Parameters
Parameter manual
b maXX
BM5800
Document No.: 5.16029.03
669
3
133.41
Anisotropy
Display of the demodulated signal after the motor diagnosis via the electrical angle. The
increment accords to 360 degrees/256 values = 1.40625 degrees.
133.51
Saliency ratio
This parameter is necessary to set the commutation controller and it displays the ratio be-
tween Lq and Ld:
If the motor parameters are not known, the commutation controller can be set in the first
step with the default value 0.1.
133.55
Damping factor
Damping gain. The high-frequency component of the Iq-I term is multiplied by this factor
and is used as an additional speed set value.
133.58
Time constant fast damping filter
Fast time constant by which the Iq-I term is filtered.
The high-frequency component of the vibration damping is determined here.
133.59
Time constant slow damping filter
Slow time constant by which the Iq-I term is filtered.
The constant component is filtered with this.
Saliency Ratio
Lq
Ld
–
Lq
------------------------
=