149.9
Spindle relative offset
The parameter is used as distance which must be driven from standstill at relative se-
quential positioning (
Mode bit 4 = 1). Only the Low-Word of the parameter is
used. The High-Word of the parameter is not used at the time and must be set to zero.
Format
High-Word: Revolutions
Low-Word: Angle
Figure 166:
Spindle relative offset
149.10
Active target position
This is the calculated target position, which must be reached in a 16 bit revolution and in
a 16 bit angle format.
The parameter is updated in the operating modes spindle positioning (-6) and target po-
sition setting (1).
149.11
Output Position Set Value
This parameter shows the actual position set value calculated from module spindle posi-
tioning.
149.12
Output speed set value
This parameter shows the output speed set value generated from module spindle posi-
tioning.
149.13
Output acceleration set value
This parameter shows the output acceleration set value generated from module spindle
positioning.