Description of the Software Modules and Parameters
Parameter manual
b maXX
BM5800
Document No.: 5.16029.03
515
3
3.8.1.4 Description of the Parameter
121.1
Positioning general mode
121.13
Input revolutions of load
gear
UDINT
1
0x7FFFFFFF
1
1.1
X
121.14
Output revolutions of
load gear
UDINT
1
0x7FFFFFFF
1
1:1
X
121.15
Modulo revolutions
UDINT
0
0x7FFFFFFF
1
1:1
X
121.16
Rotation position resolu-
tion
UDINT
0
0x7FFFFFFF
3600000
1:1
X
121.17
Modulo position actual
value
UDINT
0
0xFFFFFFFF 0
1:1
X
121.18
Status
DWORD 0x0
0xFFFFFFFF 0x0
1:1
X
121.19
Speed actual value load
basis
FLOAT
-2147483648
2147483647
0
Grad/s 1:1
X
121.20
Coarse position window UDINT
0
0xFFFFFFFF 0x2000
Inc
1:1
X
121.21
Command positive stop
drive
WORD
0x0
0x1
0x0
1:1
X
121.22
Status positive stop
drive
WORD
0x0
0xFFFF
0x0
1:1
X
121.23
Mode positive stop drive WORD
0
0xFFFF
0
1:1
X
121.24
Positive stop position
UDINT
0x0
0xFFFFFFFF 0x0
Inc
1:1
X
121.25
Monitoring window posi-
tive stop drive
UDINT
0x0
0x7FFFFFFF
0x1000
Inc
1:1
X
121.26
Offset modulo position
actual value
DINT
0x80000000
0x7FFFFFFF
0x0
1:1
X
121.27
Command value mode
WORD
0
0xFFFF
0x0002
1:1
X
121.30
Position error load basis DINT
-2147483648
2147483647
0
1:1
X
Bit
Meaning
0
1: Software limit switch monitoring ON
1
1: Hardware limit switch monitoring ON
3 ... 2
Reserved
4
1: Calculation of Modulo position actual value ON
5
1: The revolution overflows of the encoder in parameter
are
ignored at initialization of Modulo position actual value.
6
1: The position actual value (
) is set to the value of the calculated
modulo position actual value (
); the setting is relevant at an
active calculation of the modulo position actual value!