3.5
n
OPERATION ENABLED
m
The parameters for the application can be changed
m
Drive function is enabled
m
The operationally ready relay is ON (drive is operationally ready)
n
OPERATION INHIBIT ACTIVE
m
The parameters for the application can be changed
m
Drive function is enabled
m
"Inhibit Operation" command is executed
m
The operationally ready relay is ON (drive is operationally ready)
n
DRIVE SHUT-DOWN ACTIVE
m
The parameters for the application can be changed
m
Drive function is enabled
m
"Shut-down" command is executed
m
The operationally ready relay is ON (drive is operationally ready)
n
QUICK STOP ACTIVE
m
The parameters for the application can be changed
m
"Quick Stop" command is executed
m
Drive function is enabled
m
The operationally ready relay is ON (drive is operationally ready)
n
ERROR RESPONSE ACTIVE
m
The parameters for the application can be changed
m
An error-dependent action is carried out
m
Drive function can be enabled
m
The operationally ready relay is ON (drive is operationally ready)
n
ERROR
m
The parameters for the application can be changed
m
The drive function is inhibited
m
The operationally ready relay is OFF (drive is not operationally ready)