Configuration
Parameter manual
b maXX
BM5800
Document No.: 5.16029.03
Baumüller Nürnberg GmbH
164
3.4
The parameter is writable. The value
is adapted to the new counting range ac-
cording to a modulo calculation, if a smaller value than the present value of
written.
106.20
Offset sine
Offset correction for the sine signal. Automatically adjusted when optimization activated.
Can also be set as a fixed parameter.
106.21
Offset cosine
Offset correction for the cosine signal. Automatically adjusted when optimization activat-
ed.
Can also be set as a fixed parameter.
106.22
Gain sine
Amplification of the sine signal. Automatically adjusted when optimization activated.
Can also be set as a fixed parameter.
106.23
Gain cosine
Amplification of the cosine signal. Automatically adjusted when optimization activated.
Can also be set as a fixed parameter.
106.24
Sine signal
Analog value of sine trace (after correction).
At square-wave incremental encoders the measuring value of the B trace is shown. How-
ever the displayed value is only usable up to approximately 18 kHz signal frequency.
106.25
Cosine signal
Analog value of cosine trace (after correction).
At square-wave incremental encoders the measuring value of the A trace is shown. How-
ever the displayed value is only usable up to approximately 18 kHz signal frequency.