![Baumuller b maXX BM5800 Parameter Manual Download Page 152](http://html.mh-extra.com/html/baumuller/b-maxx-bm5800/b-maxx-bm5800_parameter-manual_2711380152.webp)
Configuration
Parameter manual
b maXX
BM5800
Document No.: 5.16029.03
Baumüller Nürnberg GmbH
152
3.4
3.4.6.10 Parameter overview
Functional block:
Encoder monitoring [14]
FbEncoder [106]
FbEncoderId [137]
Number
Name
Type
Min
Max
Default Value
Unit
Factor
Re
ad o
n
ly
St
o
ra
g
e
DS Su
pp
ort
Cy
clic W
rite
Ax
is-in
d
ep
ende
nt
14.1
Min value sin²+cos²
FLOAT
0
141.42
30
%
1:1
X
14.2
Max value sin²+cos²
FLOAT
0
141.42
125
%
1:1
X
14.3
Actual value sin²+cos²
FLOAT
0
141.42
0
%
1:1
X
14.4
Variance of sin²+cos²
FLOAT
0
141.42
0
%
1:1
X
14.5
Average sin²+cos²
FLOAT
0
2896
0
Inc
1:1
X
14.6
Max sin²+cos² variance
FLOAT
0
141.42
100
%
1:1
X
X
14.7
Variance quality factor
FLOAT
0
141.42
0
1:1
X
14.8
Absolute range of fluctu-
ation
FLOAT
0
141.42
0
%
1:1
X
14.9
Tolerance
FLOAT
0
141.42
50
%
1:1
X
X
14.10
Max error count ampli-
tude
UINT
0
0x001F
1
1:1
X
14.11
Error count lower limit
UINT
0
0x001F
0
1:1
X
14.12
Error count upper limit
UINT
0
0x001F
0
1:1
X
14.13
Max error count sector
UINT
0
0x001F
1
1:1
X
14.14
Error count sector
UINT
0
0x001F
0
1:1
X
14.15
Max error count incre-
mental encoder
UINT
0
0x001F
1
1:1
X
14.16
Error count incremental
encoder
UINT
0
0x001F
0
1:1
X
14.17
Encoder error mask
UDINT
0
0x7F
0x1F
1:1
X
14.19
Cycle time variance cal-
culation
UDINT
0
0x7FFFFFFF
10000
1:1
X
14.20
Status variance calcula-
tion
UDINT
0
0xFFFF
0
1:1
X
14.21
Position monitoring error
threshold
FLOAT
0.0
360.0
45.0
Grad
1:1
X
14.22
Position monitoring error FLOAT
-360.0
360.0
0
Grad
1:1
X
106.1
Encoder type
INT
0
11
0
1:1
X
106.2
Status
UINT
0
0xFFFF
0
1:1
X
106.3
Encoder options
UDINT
0
0xFFFFFFFF 0
1:1
X
106.4
Oversampling factor
UINT
0
8
0
Bit
1:1
X
106.5
Encoder actual angle
UDINT
0
0xFFFFFFFF 0
Inc
1:1
X
106.6
Encoder actual revolu-
tions
UDINT
0
0xFFFFFFFF 0
1:1
X
106.7
Speed display
DINT
0x80000000
0x7FFFFFFF
0
Inc/ms 1:1
X