![Baumuller b maXX BM5800 Parameter Manual Download Page 15](http://html.mh-extra.com/html/baumuller/b-maxx-bm5800/b-maxx-bm5800_parameter-manual_2711380015.webp)
15
Parameter manual
b maXX
BM5800
Document No.: 5.16029.03
2
C
OMMISSIONING
This chapter describes a specimen commissioning of a b maXX
multi-axis controller
BM5323 in conjunction with a BM5032 mains rectifier unit with a Baumüller DS56-S mo-
tor.
Perform the commissioning to satisfy yourself that the supplied device is functioning prop-
erly.
This commissioning does
not
constitute a complete set-up of the device for your applica-
tion.
Before the commissioning, make sure that the technical requirements are met:
1
All points, including the installation, in the b maXX
5800 Operating Manual
(5.16027) have been followed.
2
Check of the requirements for the electrical supply.
3
Check of the requirements for the electrical cables and provision of appropriate ca-
bles.
4
Check of the characteristics of the connections and manufacture of the appropriate
cables.