Description of the Software Modules and Parameters
Parameter manual
b maXX
BM5800
Document No.: 5.16029.03
103
3
107.34
Lq inductance
Quadrature axis inductance of a synchronous machine.
The value displayed is read from motors with an electronic identification plate and is used
for motor control as a function of parameter
.
107.35
Ld inductance
Direct axis inductance of a synchronous machine.
The value displayed is read from motors with an electronic identification plate and is used
for motor control as a function of parameter
.
107.36
Inertia of motor
Moment of inertia of the motor. The value displayed is read from motors with an electronic
identification plate and is for information only.
107.37
Temperature sensor type
Two different types of temperature sensor are available for use. If the motor has no elec-
tronic identification plate, the temperature sensor type must be entered.
107.38
Motor flags
Value
Meaning
0
KTY 84
1
Temperature switch or motor protection thermistor (MSKL)
2
PT1000
15 ... 3
Reserved
Bit
Meaning
0
0: Motor phase sequence counter-clockwise
1: Phase sequence clockwise
2 ... 1
00: Synchronous motor
01: Asynchronous motor
10: Interior permanent magnet synchronous motor (IPMSM)
15 ... 3
Reserved
default = 0