Configuration
Parameter manual
b maXX
BM5800
Document No.: 5.16029.03
Baumüller Nürnberg GmbH
102
3.4
107.28
Time constant I
2
t
Thermal Time Constant of the motor, T
t
[s].
107.29
Stator resistance
The displayed value accords to a motor temperature of 20° (motor cold) and is read at
motors with an electronic type key.
The parameter
107.29
can be used in dependence of
107.30
Stator leakage inductance
Leakage inductance of the single phase equivalent circuit of the asynchronous machine.
The value displayed is read from motors with an electronic identification plate and is used
for motor control as a function of parameter
107.31
Rotor resistance
Rotor resistance of the single phase equivalent circuit of the asynchronous machine. The
value displayed is read from motors with an electronic identification plate and is used for
motor control as a function of parameter
.
107.32
Rotor leakage inductance
Rotor leakage inductance of the single phase equivalent circuit of the asynchronous ma-
chine. The value displayed is read from motors with an electronic identification plate and
is used for motor control as a function of parameter
.
107.33
Magnetizing inductance
Magnetizing inductance of the single phase equivalent circuit of the asynchronous ma-
chine. The value displayed is read from motors with an electronic identification plate and
is for information only.