Controller terminals
Instruction handbook
b maXX
BM4400, BM4600, BM4700
Document No.: 5.12008.07
Baumüller Nürnberg GmbH
200
7.11
X3
Ready for use ON (SELV/PELV)
Quick stop (SELV/PELV)
Pulse enable (SELV/PELV)
Notes on the usage of an OSSD test pulse see
C.4 Requirements on an OSSD test
X5/X6
X5 IN
H51
H52
1
: TX+
2
: TX-
3
: RX+
4
: reserved
5
: reserved
6
: RX-
7
: reserved
8
: reserved
X6 OUT
H61
H62
1
: TX+
2
: TX-
3
: RX+
4
: reserved
5
: reserved
6
: RX-
7
: reserved
8
: reserved
depends on ES controller type
BM4XXX - XXX - XXXXX[Ryy] -
1X
(with EtherCAT
®
interface)
Max. cross-section
of connection
Connection
technology
Load capacity /
voltage level
1.5 mm
2
Plug-in contact
Ready for use ON; X3-1, X3-2
and X3-6:
max.
0.2
A
Quick stop; X3-4
Pulse enable; X3-5:
0 (low) 0 V to 5 V
1 (high) 12 V to 28 V
NOTE!