Controller terminals
Instruction handbook
b maXX
BM4400, BM4600, BM4700
Document No.: 5.12008.07
Baumüller Nürnberg GmbH
196
7.11
Standard
controller
Figure 91:
Connection X100 and terminals of a standard controller
X100-
1
: +24V (SELV/PELV)
1)
X100-
2
: +24V (SELV/PELV)
1)
X100-
3
: Power supply on (bus) (SELV/PELV)
2)
X100-
4
: Brake resistor on (SELV/PELV)
2)
X100-
5
: M24V (SELV/PELV)
1)
X100-
6
: M24V (SELV/PELV)
1)
UH
1
: reserved
UH
2
: reserved
H
1
:
green: torque direction 1, yellow: torque direction 2
H
2
:
green: enabling, yellow: Power ON
H
3
:
red: current limit reached
H
4
:
red: error
X4: reserved
X1, depends on controller type, see
H
5
7-segment display
4)
Display and operation elements
X2:
Connection for Baumüller memory module PSI
3) 4)
X3-
1
: Ready for use ON (normally open contact) (SELV/PELV)
X3-
2
: Ready for use ON (change over) (SELV/PELV)
X3-
3
: Reference for 4 and 5 (SELV/PELV)
X3-
4
: Quick stop (SELV/PELV)
X3-
5
: Pulse enable (SELV/PELV)
X3-
6
: Ready for use ON (normally closed contact) (SELV/PELV)
Summary of Contents for b maxx BM4400
Page 359: ......