T
6
Installation
Connector
Quantity
Usage
Type
X101
1
motor temperature
COMBICON MC 1.5/2-ST-3.5
X205
1
chopper resistor, UDC link
connection
COMBICON IC 2,5/5-ST-5,08
X204
1
motor connection
COMBICON IC 2,5/4-ST-5,08
X101-1, MT+
X101-2, MT-
X205-1, 1D1
X205-2, 1C1
X205-3, Ba+
X205-4, Ba-
X205-5, BaI
X204-1, 1W2
X204-2, 1V2
X204-3, 1U2
X204-4, PE
Figure 6.25: Connections at the bottom of HS1 for type key V2
NOTE
If connection X101 is used in order to connect the motor temperature cable, the screen must
be applied flat and as near as possible to the housing of the
b maXX® BM3400
. It is necessary
to use a cable with
separate screening
for the temperature sensor lines (also see «Appendix B
- Spare parts and accessories» from page
). At an improper or missing screening you may
reckon, that there will be great EMC problems!
84
Instrution
Manual
b
maXX®
BM3400
from
206
Do
ument
No.:
5.07013.03
Baumueller
Kamenz
GmbH
Summary of Contents for b maXX BM3400 Series
Page 1: ...E 5 07013 03 Instruction Manual b maXX BM3400 ...
Page 2: ......
Page 4: ......
Page 195: ...F Appendix F Index Instru tion Manual b maXX BM3400 195 Do ument No 5 07013 03 from 206 ...
Page 204: ......
Page 205: ... ...