Connetion
diagrams
6.12
T
Connector
Quantity
Usage
Type
X101
1
motor temperature
COMBICON MC 1.5/2-ST-3.5
X205
1
chopper resistor, UDC link
connection
COMBICON IC 2.5/4-ST-5.08
X204
1
motor connection
COMBICON IC 2,5/4-ST-5,08
X101-1, MT+
X101-2, MT-
X204-1, PE
X204-2, 1W2
X204-3, 1V2
X204-4, 1U2
X205-1, Ba-
X205-2, 1D1
X205-3, 1C1
X205-4, PE
Figure 6.15: Connections at the bottom of HS0 for type key V1
NOTE
If connection X101 is used in order to connect the motor temperature cable, the screen must
be applied flat and as near as possible to the housing of the
b maXX® BM3400
. It is necessary
to use a cable with
separate screening
for the temperature sensor lines (also see «Appendix B
- Spare parts and accessories» from page
). At an improper or missing screening you may
reckon, that there will be great EMC problems!