![Baumuller b maXX BM2500 Operating Manual Download Page 641](http://html.mh-extra.com/html/baumuller/b-maxx-bm2500/b-maxx-bm2500_operating-manual_2711400641.webp)
Description of the Software Modules and Parameters
Parameter manual
b maXX
BM3000
Document no.: 5.12001.07
641
4
4.8.8.1 ProDrive Notch Position Search
Figure 210:
ProDrive Find Notch Position
4.8.8.2 Parameter overview
Functional block:
FbNotchPosition [127]
Parameters 19.50 and 19.51, refer to
Number
Name
Type
Min
Max
Default Value
Unit
Factor
Read o
n
ly
St
o
ra
g
e
DS Supp
ort
Cyclic W
rite
127.1
Init. pos. detection method
INT
0
3
0
1:1
X
127.4
Max. current notch position
FLOAT
0
20000
0
A
1:1
X
127.5
Current rise
FLOAT
0.001
100
1
A/s
1:1
X
127.6
Current drop
FLOAT
0.001
100
5
A/s
1:1
X
127.7
Duration constant current
FLOAT
0
10
1
s
1:1
X
127.8
Encoder offset el.
UINT
0
0xFFFF
0
Grad
1:1
X
127.9
Maximum angle
UINT
1
0xFFFF
0x005b
Inc
1:1
X
127.10
Angle rising
UINT
1
0xFFFF
1
Inc/ms 1:1
X