Description of the Software Modules and Parameters
Parameter manual
b maXX
BM3000
Document no.: 5.12001.07
481
4
Figure 160:
ProDrive Current controller adaption
4.7.2.8 Overview of Current Controller Parameters
Functional block:
Current Controller [47]
For parameter number 18.45, see
For parameter numbers 107.20 and 138.ff, see
Number
Name
Type
Min
Max
Default Value
Unit
Factor
R
ead o
n
ly
St
o
ra
g
e
D
S
Su
pp
ort
C
yclic W
rite
47.1
Isq set value
FLOAT
-10000
10000
0
A
1:1
X
47.2
Isd set value
FLOAT
-10000
10000
0
A
1:1
X
47.3
Isq actual value
FLOAT
-10000
10000
0.0
A
1:1
X
47.4
Isd actual value
FLOAT
-10000
10000
0.0
A
1:1
X
47.5
Isq act value filtered
FLOAT
-10000
10000
0.0
A
1:1
X
47.6
Isd act value filtered
FLOAT
110000
10000
0.0
A
1:1
X
47.7
P-Gain 4kHz Iq
FLOAT
0.0
1.0e+04
10.0
V/A
1:1
X
X
47.8
Integral action time Iq
FLOAT
0.0
1.0e+04
5.0
ms
1:1
X
X
47.9
P-Gain 4kHz Id
FLOAT
0.0
1.0e+04
10.0
V/A
1:1
X
X
47.10
Integral action time Id
FLOAT
0.0
1.0e+04
5.0
ms
1:1
X
X
47.20
Usq set value
FLOAT
-440
440
0.0
V
1:1
X
47.21
Usd set value
FLOAT
-440
440
0.0
V
1:1
X
47.22
Integral term Usq
FLOAT
-440
440
0.0
V
1:1
X
47.23
Integral term Usd
FLOAT
-440
440
0.0
V
1:1
X
47.24
Usq control output
FLOAT
-440
440
0
V
1:1
X
47.25
Usd control output
FLOAT
-440
440
0
V
1:1
X
47.26
Back-EMF feed forward
FLOAT
-440
440
0.0
V
1:1
X