4.5.2.9 Data Set Commands and Possible Error Messages
m
Reset the Data Set Management System
This command results in a reset of the message list and the status word of the Data Set
Management System.
n
Possible error messages:
None
m
Write all parameters to Flash memory
This data set command saves all the parameters in the created data sets from RAM to
Flash.
m
Load parameters from Flash
This command reads all the parameters from Flash into the RAM of the device. This com-
mand is only possible when the device is locked.
During the copying procedure, any changeover of the data sets is inhibited.
Possible error messages:
n
Device is not inhibited
n
Value less than minimum value
n
Value greater than maximum value
n
Parameter is read-only
n
Due to operating state, parameter cannot be changed
n
Parameter value is invalid
n
Check yielded faulty checksum
m
Delete parameters in Flash
This data set command deletes the parameters saved in Flash.
Possible error messages:
n
Error writing to Flash
m
Set standard values for all savable parameters
All savable parameters of the device are set to their standard values. This command is
only possible when the device is locked.
m
Create Data Set <n>
When a device is delivered, initially only a single data set (Data Set 1) is activated. The
user cannot switch to other data sets, therefore. Only after the user has created a further
data set (2 to 7) using this command will the device allow switching to this data set. This
measure is intended to guarantee that the user cannot switch unintentionally to an as yet
unmodified data set. He is thus compelled to consciously enable a data set for the
changeover.
This data set command creates a data set which is selected with
Target Data
Set. The parameter values for this data set (the data set parameter only) are set to their
standard values in the process.