4
108.17
Mask for status internal limit
Mask for the status bit string for internal limits (InternalLimitStatus)
This parameter is used to select which internal limits will be reported in Status Word 1,
Bit 11.
Bit in mask = 1: Limit is shown in Status Word 1
108.18
Delay for Quick Stop input
Settable delay for the response to the activation of Quick Stop by the Quick Stop
digital
input
(has no effect if the "Quick Stop" command was issued by Control Word 1 (Param-
eter
)).
The initiation of the Quick Stop response is delayed by the preset time; the drive remains
enabled during this time.
108.19
Time for reducing torque
This parameter can be set to provide smooth torque reduction using controlled braking
procedures. After the drive has been braked to Speed 0, the internal torque current limit
is reduced linearly to 0 over the set time and the drive is then inhibited. This smooth re-
duction of torque is effective for all braking procedures controlled by the drive manager,
i.e., for the "Inhibit Operation", "Shut Down Drive" and "Quick Stop" commands, provided
a braking procedure with subsequent transition to an inhibited state is set as a response
to the corresponding command. Furthermore the smooth reduction of torque also oper-
ates for error reactions where a braking procedure is initiated.
3
Reserved
4
1: Negative HW limit switch is set (even if not limited)
5
1: Positive HW limit switch is set (even if not limited)
6
1: Negative SW limit switch is set (target position was outside, now limited)
7
1: Positive SW limit switch is set (target position was outside, now limited)
8…31
Reserved
Bit no.
Meaning