4.5
108.14
SHUTDOWN reaction code
See also
This parameter defines the response of the drive during the transition from the OPERA-
TION ENABLED to the READY TO SWITCH ON state in the state machine for the device
controller.
For correct functioning of the braking procedures on the Quick Stop or Ramp-down
ramps, the speed controller must be adequately configured.
108.15
DISABLE OPERATION reaction code
See also
This parameter defines the response of the drive during the transition from the OPERA-
TION ENABLED to the SWITCHED ON state in the state machine for the device control-
ler.
For correct functioning of the braking procedures on the Quick Stop or Ramp-down
ramps, the speed controller must be adequately configured.
108.16
Status internal limits
Status bit string for internal limits
Value
Meaning
0
Inhibit drive immediately
1
Return to ramp-down ramp
2
Return to Quick Stop ramp
3
Return to current limit
Value
Meaning
0
Inhibit drive immediately
1
Return to ramp-down ramp
2
Return to Quick Stop ramp
3
Return to current limit
Bit no.
Meaning
0
1: Current/torque limited
1
1: Speed set value limited at speed controller input
2
1: Speed limited during set value generation