Description of the Software Modules and Parameters
Parameter manual
b maXX
BM3000
Document no.: 5.12001.07
311
4
4.4.22.7 Description of the Parameters
170.1
PLC control word
Controls the start-up behavior and start/stop behavior (stop, cold start, warm start, hot
start) for the SoftDrivePLC.
170.2
PLC Status
Status of the SoftDrivePlc
170.20
Write event parameter UINT UINT
0
0xFFFF
0
1:1
X
170.21
Write event parameter
UDINT
UDINT
0
0xFFFFFFFF 0
1:1
X
170.22
Write event parameter REAL FLOAT
0
0xFFFFFFFF 0
1:1
X
170.30
Error code
UDINT
0
0xFFFFFFFF 0
1:1
X
170.31
Error module number
UINT
0
0xFFFF
0
1:1
X
170.32
Error line number
UINT
0
0xFFFF
0
1:1
X
170.33
Error POU Code type
UINT
0
0xFFFF
0
1:1
X
170.34
Error module name
STRING
1:1
X
170.50
Run time task RT0
FLOAT
0
5000000000
0
µs
1:1
X
170.51
Run time task RT1
FLOAT
0
5000000000
0
µs
1:1
X
170.52
Run time task RT2
FLOAT
0
5000000000
0
µs
1:1
X
170.53
Run time fieldbus task
FLOAT
0
5000000000
0
µs
1:1
X
170.54
Run time write event task
FLOAT
0
5000000000
0
µs
1:1
X
Value
Meaning
0
PLC stop
1
PLC cold start
All variables will be initialized with default values
2
PLC warm start (behavior as cold start)
3
PLC hot start
No variables are initialized.
4 ... 65535 Reserved