4.4
154.3
Lower speed threshold
Lower speed limit (speed limit for the left-hand sided switching threshold)
154.4
Upper speed threshold
Upper speed limit (speed limit for the right-hand sided switching threshold)
154.5
Output value 1
Connected friction compensation value for
Speed < Lower speed limit
154.6
Output value 2
Connected friction compensation value for
Lower speed limit
Speed < Upper speed limit
Effective only if connection „Three-point with hysteresis and dead zone“ (
Bit 2…1 = 00).
154.7
Output value 3
Connected friction compensation value for
Speed > Upper speed limit
154.8
Friction compensation actual output value
Connected friction compensation value at the moment.
154.9
Hysteresis speed threshold
Hysteresis for connection „Three-point with hysteresis and dead zone“ (
Bit 2…1 = 00), otherwise not effective.