4.4
This parameter must be sent cyclic from the master to the slave.
At external master-slave communication this parameter must be sent via cross commu-
nication (fieldbus) or analog inputs/outputs. See also
283.
147.20
Torque init stress actual value
Display of the present torque init stress. It is dependent on place and connection of the
torque init stress.
1
Torque init stress acts via compensating controller (
Bit 16 = 0)
m
Master:
No Meaning
m
Slave:
Display of the present torque init stress which is parameterized and generated of the
slave.
2
Torque init stress acts directly on the torque set values (
Bit 16 = 1)
m
Master:
Display of the present torque init stress which is parameterized and generated of the
master.
m
Slave:
Display of the present torque init stress which is parameterized and generated of the
master and sent to the slave.
147.21
Torque init stress actual value master
Display of the present torque init stress of the master at torque coupling in the format for
transmission via fieldbus. It is dependent on place and connection of the torque init stress.
1
Torque init stress acts via compensating controller (
Bit 16 = 0)
No Meaning
2
Torque init stress acts directly on the torque set values (
Bit 16 = 1)
m
Master:
Display of the present torque init stress which is parameterized and generated of the
master.
This parameter must be sent cyclic from the master to the slave.
At external master-slave communication this parameter must be sent via cross com-
munication (fieldbus) or analog inputs/outputs. See also
m
Slave:
Display of the present torque init stress which is parameterized and generated of the
master and sent to the slave.