![Baumuller b maXX BM2500 Operating Manual Download Page 281](http://html.mh-extra.com/html/baumuller/b-maxx-bm2500/b-maxx-bm2500_operating-manual_2711400281.webp)
Description of the Software Modules and Parameters
Parameter manual
b maXX
BM3000
Document no.: 5.12001.07
281
4
Torque init stress only on slave-side via compensating controller
The torque init stress is parameterized and calculated on the slave axis and is connected
to the input of the speed controller via the compensating controller as speed additional
set value.
Thus the torque init stress acts upon the slave axis only.
Figure 112:
Structure of the control of the torque coupling at connecting the torque coupling via compensating controller
-
-
x
x
-
P147.4 Bit 0
0
1
P147.13
P147.9
P147.10
P147.7
P147.8
P147.18
5000_0179_rev01_int.cdr
n
Set
Coupling
factor
slave
P147.6
Compensating controller
Coupling
factor
master
P147.5
nact
Slave
Master
m
Set,slave
m
Set,master
m
Set,master
P147.19
nact
Cross communication
Coupling
command
P147.4
Torque init
stress Mv
Stress