![Baumuller b maXX BM2500 Operating Manual Download Page 194](http://html.mh-extra.com/html/baumuller/b-maxx-bm2500/b-maxx-bm2500_operating-manual_2711400194.webp)
Configuration
Parameter manual
b maXX
BM3000
Document no.: 5.12001.07
Baumüller Nürnberg GmbH
194
4.4
137.22
Firmware version
Firmware version of the encoder.
The version of the EnDat
®
interface is displayed at EnDat
®
encoder. Only the incompat-
ible part of the version will be displayed. The compatible part (to the right of the decimal
point) is missing.
137.23
Firmware date
Date of the encoder firmware version.
137.24
Eprom capacity
Size of the usable OEM memory
137.25
Data storage capacity
Total storage capacity of the encoder
137.26
Defined fields
Only for Stegmann encoders: number of defined OEM memory data fields
137.27
Data field status
Only for Stegmann encoders: status of the defined data fields. See Stegmann manual for
meaning
137.28
Digital resolution
The parameter shows the resolution oft he the digital position in bits per revolution. It is
operated only with rotary encoder with EnDat
- or Hiperface
-encoders.