![Baumuller b maXX BM1000 Manual Download Page 102](http://html.mh-extra.com/html/baumuller/b-maxx-bm1000/b-maxx-bm1000_manual_2711384102.webp)
Environmental conditions
Manual
b maXX
®
BM1000
Document No. 5.07003.04
Baumüller Nürnberg GmbH
102
9.2
9.2
Environmental conditions
If the prescribed environmental conditions are complied with, the device is maintenance-
free. The prescribed environmental conditions are to be found in chapter
from page 141. The most important prescribed environmental conditions
are:
m
Dustless ambient air
m
Temperature:
min. -10 °C to max. +50 °C (14 - 122 °F)
min. -10 °C to max +40 °C (14 - 104 °F)
for side-by-side mounting
m
Relative air humidity:
0 to 90 %, no condensation allowed
m
(Operational-) height:
Altitude up to 1000 m
m
Atmosphere pressure:
86 - 106 kPa
m
Vibration:
<20 Hz: 9.80 m/s² (1 G) max.
20 - 50 Hz: 5.88 m/s² (0.6 G)
9.3
Inspection intervals - maintenance notes
b maXX
®
1000
drives are based on solid-state electronics technology. Preventive main-
tenance is required to keep the device in its optimal condition, and to ensure a long life.
It is recommended to have a qualified technician perform a check-up of the device regu-
larly.
Daily inspection:
Basic check-up items to detect if there were any abnormalities during operation are:
m
Whether the motors are operating as expected.
m
Whether the installation environment is abnormal.
m
Whether the cooling system is operating as expected.
m
Whether any irregular vibration or sound occurred during operation.
m
Whether the motors are overheating during operation.
m
Always check the input voltage of the device with a voltmeter.
Periodic inspec-
tion:
Before the check-up, always turn off the input power and remove the cover. Wait at least
10 minutes after all display lamps have gone out, and then confirm that the capacitors
have fully discharged by measuring the voltage between
and
. It should be less
than 25 V
DC
.
DANGER
The following
will occur
,
if you do not observe this danger information:
m
serious personal injury
m
death
The hazard is: electricity.
m
Disconnect power before processing!
m
Only qualified personnel shall install, wire and maintain the devices. Please take off any
metal objects, such as watches and rings, before operation. And only insulated tools are
allowed.
m
Never reassemble internal components or wiring.
m
Prevent electric shocks.
Summary of Contents for b maXX BM1000
Page 1: ...E 5 07003 04 Manual b maXX BM1000 Basic unit ...
Page 108: ...Manual b maXX BM1000 Document No 5 07003 04 Baumüller Nürnberg GmbH 108 of 174 ...
Page 118: ...Manual b maXX BM1000 Document No 5 07003 04 Baumüller Nürnberg GmbH 118 of 174 A ...
Page 172: ...Manual b maXX BM1000 Document No 5 07003 04 Baumüller Nürnberg GmbH 172 of 174 Index ...
Page 174: ...Manual b maXX BM1000 Document No 5 07003 04 Baumüller Nürnberg GmbH 174 of 174 Notes ...
Page 175: ......