![Baumuller b maXX 5000 Instruction Handbook Manual Download Page 99](http://html.mh-extra.com/html/baumuller/b-maxx-5000/b-maxx-5000_instruction-handbook-manual_2711361099.webp)
Design and Operation
Instruction handbook
b maXX
5000
Document No.: 5.09021.16
99
4
LED
POWERLINK
®
.
Type code
BM5XXX-XXXX-XXXX-
04
XX
Naming on the
front plate
H31 (green)
X3 Link / Act
Off:
No connection
On:
Connection
Blinking:
Data transfer
H32 (yellow)
ERROR
Off:
NMT_CT3, NMT_CT7, NMT_GT2
On:
NMT_CT11, NMT_GT6
Blinking:
Configuration error (e.g. address seting)
H41 (green)
X4 Link / Act
Off:
No connection
On:
Connection
Blinking:
Data transfer
H42 (green)
STATUS
Off:
NMT_GS_OFF, NMT_GS_INITIALISATION,
NMT_CS_NOT_ACTIVE
50 ms off /
50 ms on: NMT_CS_BASIC_ETHERNET
200 ms on /
1 s off:
NMT_CS_PRE_OPERATIONAL_1
2 x 200 ms on /
1 s off:
NMT_CS_PRE_OPERATIONAL_2
3 x 200 ms on /
1 s off:
NMT_CS_READY_TO_OPERATE
On: NMT_CS_OPERATIONAL
200 ms on /
200 ms off: NMT_CS_STOPPED
Meaning