Electrical data
Instruction handbook
b maXX
5000
Document No.: 5.09021.16
Baumüller Nürnberg GmbH
58
3.4
3.4
Electrical data
3.4.1
Electrical data BM50XX; BM51XX
m
BM50
30
mains rectifier unit
without
safety function
BM50
30
-
X
T0
X
-.. /-
X
I0
X
-.. / -
X
G0
X
-..
without charge resistor
BM50
30
-
X
R0
X
-.. /-
X
S0
X
-.. / -
X
W0
X
-..
with charge resistor
Input rated power
1)
6 kVA
6.9 kVA
14)
Input rated current (I
eff
)
1) 2) 3)
8.5 A
10.4 A
Distortion factor of the input current (THD
I
)
1)
57 % ± 10 %
160 % ± 10 %
Input peak current (I
eff
)
1) 2) 3)
12.5 A for max. 150 s
15.6 A for max. 150 s
DC link voltage, power supply dependent/rated
540 V
DC
at U
power supply
= 3 x 400 V
Internal DC link capacitance (C
int
)
470 µF
DC link discharge time (C
int
)
9)
Approx. 450 s
Waiting period between 2 charging processes
(no external DC link capacitance)
36 s
Total maximum connectable capacitance in the
DC link
7.8 mF
in external
Waiting time between 2 charging processes
with maximum capacitance
600 s
13)
Connection power at DC link
1) 5)
5 kW
Peak power at DC link
4) 6)
7.5 kW for max. 150 s
Ready-to-operate after
7 s
Max. charge-up time
10 s
External brake resistor R
B
R
B
33
External brake resistor continuous power
5 kW
Quick discharge resistor
-
Power loss with regard to power supply
7)
40 W
Power loss with regard to control voltage
supply
8)
Max. 10 W
Cooling air requirement power heat sink
40 m
3
/h
Cooling air velocity power heat sink
-
Cooling air requirement internal space of device
8 m
3
/h
Footnotes refer to
.