![Baumuller b maXX 5000 Instruction Handbook Manual Download Page 258](http://html.mh-extra.com/html/baumuller/b-maxx-5000/b-maxx-5000_instruction-handbook-manual_2711361258.webp)
Cabling
Instruction handbook
b maXX
5000
Document No.: 5.09021.16
Baumüller Nürnberg GmbH
258
11.1
11.1.9.5 Connecting cable for sine/square-wave incremental encoder
The connecting cable is available as accessory part from Baumüller Nürnberg GmbH.
Follow the instructions below if a self-made cable is to be used:
1
Utilize the following materials:
m
Cable: Li9YC3x2x0.25-Li9Y3x2x0,25-Li9Y C11Y 1x2x0.34GN. Two cable pairs are
not needed and also not connected.
m
High-density D-sub connector: 26-pin, male
m
Round connector: 12-pin, female (e.g. from Interconnectron)
2
Fully adjoin the cable shield with the housing of the round connector and with the
shielding of the D-sub connector.
5000_1
103_rev01_int.cdr
2
1
4
5
6
8
9
12
11
17
18
7
12
10
5
6
8
3
4
2
11
7
9
1
Æ
0.34 mm
Æ
0.34 mm
Figure 113:
Connecting cable for sine/square wave incremental encoder
NOTE
The connecting cable must be made according to the figure shown above!
If there is a different pin assignment, the cable is not functionally operable and could
lead to defects, both in the encoder module and the encoder!